Wiring methods & materials: Minnesota Class A Journeyworker Electrician Practice Questions

General wiring rules, underground installations, boxes and fill, cables, raceways.
Question 1
According to the NEC, what is the general rule for the conductors of one circuit, including the grounded conductor and EGC?
Question 2
According to the NEC, conductors of 120/240 V and 480Y/277 V systems may share a raceway when:
Question 3
According to the NEC, when NM cable runs through bored holes in wood studs, the edge of the hole must be at least how far from the nearest edge of the stud?
Question 4
According to the NEC, if a bored hole cannot be kept far enough from the stud edge, the cable must be protected by a steel plate at least how thick?
Question 5
According to the NEC, where NM cable is laid in a notch cut in a wood stud, what is required?
Question 6
According to the NEC, when NM cable passes through punched holes in metal studs, what is required?
Question 7
According to the NEC, a cable run parallel to framing members must be installed so it is at least how far from the nearest edge of the framing?
Question 8
According to the NEC, cables and raceways installed under metal-corrugated sheet roof decking must be kept at least how far from the lowest surface of the decking?
Question 9
According to the NEC, when 4 AWG or larger insulated conductors enter a cabinet through a raceway, what protects the conductors?
Question 10
According to the NEC table of minimum cover requirements, what is the minimum cover for direct-buried cable under a lawn (no traffic, not under a building)?
Question 11
According to the NEC table of minimum cover requirements, what is the minimum cover for rigid metal conduit in the general case?
Question 12
According to the NEC table of minimum cover requirements, PVC conduit listed for direct burial without concrete encasement needs what minimum cover in the general case?
Question 13
According to the NEC table of minimum cover requirements, a residential 120 V, 20 A GFCI-protected branch circuit buried in a yard may have a minimum cover of:
Question 14
According to the NEC table of minimum cover requirements, what is the minimum cover for any wiring method under a public street, road or alley?
Question 15
According to the NEC, direct-buried conductors that emerge from grade must be protected by enclosures or raceways up to what height above finished grade?

Ready for the real exam?

Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.
PrivacyTerms
© 2026 Trovyn Tech LLC