Venting: New Jersey Master Plumber (UPC) Practice Questions
Vent terminals, connections and grades, trap-to-vent distance, vent sizing, wet, circuit, island and combination venting, AAVs.
Often missed
Question 1
What is the main purpose of a plumbing vent system?
Correct answer: To protect trap seals
IPC 2021 901.2 / UPC 2021 901.2
Vents let air in and out of the drainage system so the flow of waste does not suck or push the water out of the traps; they also carry sewer gas outdoors.
Question 2
How many vent pipes must extend to the outdoors from a building's drainage system?
Correct answer: At least one
IPC 2021 904.1 / UPC 2021 901
Every building drainage system needs at least one vent extending to the outdoors to relieve positive pressure; AAVs cannot replace it.
Question 3
Under the UPC, a vent through the roof must end at least how high above the roof?
Correct answer: 6 inches
UPC 2021 906.1
The UPC requires vents to extend at least 6 inches above the roof and stand at least 12 inches from any vertical surface.
Question 4
A roof is used as a deck where people gather. How high must vent pipes extend above it?
Correct answer: 7 ft
IPC 2021 903.1.2 / UPC 2021 906.3
Where a roof is used for assembly, recreation or similar purposes, vents must rise at least 7 ft above it so sewer gas is released above people's heads.
Question 5
A vent terminal is 6 ft horizontally from an operable window. How high above the top of the window must it be?
Correct answer: At least 3 ft
IPC 2021 903.5 / UPC 2021 906.2
Vent terminals within 10 ft horizontally of a door, operable window or air intake must be at least 3 ft above its top, and never directly beneath it.
Question 6
Which vent terminal location is prohibited?
Correct answer: Directly below an operable window
IPC 2021 903.5 / UPC 2021 906.2
A vent may never end directly beneath a door, operable window or air intake. Beyond 10 ft horizontally, or 3 ft above the top of the opening, it is acceptable.
Question 7
A vent pipe extending through the roof is used to hold up a TV antenna. Is this allowed?
Correct answer: No, it may not support anything
IPC 2021 903 / UPC 2021 906
Vent terminals may not be used as flagpoles, antenna masts or supports; the load can break joints and flashing.
Question 8
How must horizontal vent piping be graded?
Correct answer: To drain back to the drain it serves
IPC 2021 905.2 / UPC 2021 905.1
Vents collect condensation and rain, so they slope back to drain by gravity into the drainage system.
Question 9
Where must a dry vent connect to a horizontal drain?
Correct answer: Above the centerline of the drain
IPC 2021 905.3 / UPC 2021 905.2
A dry vent taken off below the centerline would fill with waste and clog; it must connect above the centerline, rising at an angle toward vertical.
Question 10
A dry vent rises from a lavatory drain. How high must it rise before it turns horizontal?
Correct answer: 6 inches above the flood level rim
IPC 2021 905.4 / UPC 2021 905.3
Rising 6 inches above the flood level rim before going horizontal keeps the horizontal vent from becoming a drain if the fixture backs up.
Question 11
A branch vent connects to a vent stack. How high must the connection be?
Correct answer: 6 inches above the highest fixture's flood rim
IPC 2021 905.5 / UPC 2021 905.3
The connection to the vent stack or stack vent is kept at least 6 inches above the highest fixture's flood level rim, so a backup cannot enter the vent.
Question 12
Under the UPC, what is the maximum length of a 1-1/2-inch trap arm?
Correct answer: 3 ft 6 in
UPC 2021 1002.2
The UPC limits a 1-1/2-inch trap arm to 3 ft 6 in from the trap weir to the vent. The IPC allows 6 ft.
Question 13
Under the UPC, what is the maximum length of a 2-inch trap arm?
Correct answer: 5 ft
UPC 2021 1002.2
The UPC limits a 2-inch trap arm to 5 ft. The IPC allows 8 ft for a 2-inch fixture drain.
Question 14
Under the UPC, what is the maximum length of a 3-inch trap arm?
Correct answer: 6 ft
UPC 2021 1002.2
The UPC limits a 3-inch trap arm to 6 ft. The IPC allows 12 ft.
Question 15
What is the minimum distance between a trap weir and the vent connection?
Correct answer: Two pipe diameters
IPC 2021 909.3 / UPC 2021 1002.2
A vent closer than two pipe diameters to the weir acts like a crown vent and clogs. Both codes require at least two diameters.
Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.