Feeders: Texas Journeyman Electrician Practice Questions

Feeder sizing, continuous loads, feeder grounding and voltage drop.
Often missed
On the real exam: about 3 code questions and 3 calculations from this topic.
Question 1
Which conductors are "feeders"?
Question 2
Feeder conductors that supply continuous and noncontinuous loads must have an ampacity of at least:
Question 3
The equipment grounding conductor run with a feeder is sized based on:
Question 4
Calculation
A feeder supplies 80 A of continuous load and 30 A of noncontinuous load. What minimum ampacity must the feeder conductors have (no adjustment or correction factors)?
Question 5
According to the NEC, the conductors running from the main service panel of a house to a subpanel in a detached garage are:
Question 6
According to the NEC, unless the equipment is listed for 100% operation, feeder conductors must have an ampacity of at least the noncontinuous load plus what percentage of the continuous load?
Question 7
According to the NEC, the rating of a feeder overcurrent device must be at least:
Question 8
According to the informational note in the NEC feeder rules, what voltage drop limits give reasonable efficiency of operation?
Question 9
According to the NEC, when a feeder carries the total load supplied by service conductors with an ampacity of 55 A or less, the feeder ampacity must be:
Question 10
According to the NEC, a common neutral may serve up to how many sets of 3-wire feeders?
Question 11
According to the NEC, when feeders share a common neutral and are installed in a metal raceway, what is required?
Question 12
According to the NEC, before a feeder installation begins, what may the authority having jurisdiction require?
Question 13
According to the NEC, when must a feeder include an equipment grounding conductor?
Question 14
According to the NEC, the equipment grounding conductor run with a feeder is sized based on:
Question 15
According to the NEC, if feeder ungrounded conductors are increased in size to reduce voltage drop, what happens to the wire-type equipment grounding conductor?

Ready for the real exam?

Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.
PrivacyTerms
© 2026 Trovyn Tech LLC