Type III recovery: EPA 608 Practice Questions

25 mm Hg absolute, liquid then vapor, water circulation, 0 psig and nitrogen rules.
Often missed
Question 1
To what level must a low-pressure appliance be evacuated before a major repair or disposal?
Question 2
25 mm Hg absolute is about how many inches of mercury of vacuum on a compound gauge at sea level?
Question 3
Does the required evacuation level for a low-pressure appliance depend on whether the recovery equipment was made before or after November 15, 1993?
Question 4
When recovering refrigerant from a low-pressure chiller, what should be removed first?
Question 5
Even after all the liquid is removed from a large low-pressure chiller, why must vapor recovery continue?
Question 6
During recovery from a low-pressure chiller, why should water be kept circulating through the tubes (or the tubes drained)?
Question 7
Recovery equipment made on or after January 1, 2017 for use with a low-pressure chiller (non-flammable refrigerant) is certified under which standard?
Question 8
Before a non-major repair on a low-pressure chiller, with no release expected afterward, what pressure must the chiller be at?
Question 9
An R-123 chiller (boiling point about 82°F) must be raised to 0 psig for a non-major repair. May nitrogen be used to do this?
Question 10
For a low-pressure refrigerant that boils above 85°F, how may the appliance be brought to 0 psig for a non-major repair?
Question 11
What pressure applies when changing the oil on a low-pressure chiller?
Question 12
Why is the oil in a low-pressure chiller heated before it is drained?
Question 13
A low-pressure chiller has a leak that prevents reaching 25 mm Hg absolute without pulling in air. What does the rule require?
Question 14
Which recovery equipment may be used to evacuate a low-pressure chiller to 25 mm Hg absolute?
Question 15
After a low-pressure chiller reaches 25 mm Hg absolute, the technician isolates it and the pressure rises within a few minutes. What should be done?

Ready for the real exam?

Get every question, unlimited calculation practice and timed mock exams in the app.
Coming soon
Download on the App Store
Coming soon
Get it on Google Play
Not affiliated with any state agency, TDLR, PSI, NFPA, EPA or CSLB. NEC® and National Electrical Code® are registered trademarks of NFPA.
Practice questions are written in our own words and cite code sections by number. Always study from your own copy of the code and the official candidate bulletin.
PrivacyTerms
© 2026 Trovyn Tech LLC